Mercedes C 180
Lean mixture and low fuel pressure
On this 2019 C-Class W205 petrol, equipped with engine M274.910, the reading combines P217700 and P008700. The driver initially reported no discomfort. What can explain the two codes together?
Reading the two faults
Insufficient fuel supply can explain both the loss of fuel pressure and a lean mixture. An intake air leak could explain a lean mixture on its own. Comparing the readings helps distinguish these hypotheses.
Avenues to explore
Insufficient flow rate feed pump
If the pump supplies too little fuel, the pressure can drop and the mixture becomes lean. This lead can explain both codes together.
Partially clogged power circuit
Restricted fuel passage can reduce delivery and pressure. The codes alone cannot distinguish it from an insufficient pump.
Insufficient high pressure production
A high pressure pump that is not supplying demand can also explain both codes. The upstream power supply must be checked before incriminating it.
Unaccounted for air entry into the intake
An air intake can explain the lean mixture, but it does not directly explain the low fuel pressure. Diagolia retains this distinction.
The proposed controls
Check flow, pressure and pump control.
Distinguish a faulty pump from a circuit restriction or a control and power supply fault.
Compare the flow and pressures in the fuel path.
Locate a possible restriction before attributing the lack of fuel to the pump.
Compare the requested and measured rail pressure with the upstream supply and regulation.
Disconnect a fault specific to high pressure and a lack of fuel arriving from the low pressure circuit.
Check the intake for leaks and compare the results with the fuel trim readings.
Check if this track explains the lean mixture, without automatically attributing the second fault to it.
Assessment declared by the technician
Replacement of the low pressure pump with the reference updated by the manufacturer.
Engine light off. More responsive engine.
The repair and its result are indicated. Intermediate measures are not detailed in this return.