All diagnostic cases

Opel Combo

The P2413 fault persists after cleaning the EGR

On a Combo 1.5 diesel, the engine warning light and P2413 remain present after cleaning the EGR valve. The file allows you to choose what to check before replacing the valve.

The starting point

The owner describes the disassembly and cleaning of the valve. The EGR performance fault persists. This public feedback does not specify the status of the code, the detection conditions, or the measured flow rate.

What cleaning leaves to check

A clean valve guarantees neither its response to the command nor the effective circulation of gases. The connections that have been manipulated constitute a first check point. The power and engine code remain to be confirmed to choose the appropriate procedure.

The proposed controls

Note the associated codes and available conditions. Examine the intakes and connections, then compare the EGR setpoint, reported position and airflow response when this data is accessible. A deviation helps to distinguish a fault in control, measurement or gas flow.

No post-intervention measures or resolution are reported. The replacement proposed in the discussion remains a hypothesis.

Owner's testimony